Below groundbearing concrete slab

Key Properties

QUINN-therm

  • does not readily absorb water, making it suitable for use in damp environments;
  • is light, robust and easy to handle; it may be worked using a saw or sharp knife;
  • is durable and will perform for the service life of the building.


Meeting Regulations


Required thicknesses of QUINN-therm QF (mm)
Required U-value (W/m2K) P (exposed perimeter, m) / A (floor area, m2)
  0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
0.37 25 25 25 25 25 30 30 30 35 35
0.25 25 25 40 45 50 55 60 60 65 65
0.22 25 30 50 60 65 70 70 75 75 75
0.20 25 40 60 65 75 80 80 85 85 90

* The above table is a guideline - contact Quinn Technical Services department for more information.
Results based upon floor construction of:
QUINN-therm QF, 150mm concrete, 19mm timber boarding (floor finish omitted).
150mm depth of QUINN-therm QF vertical edge insulation.
Calculations performed to BS EN ISO 13770.


Design Notes

  • QUINN-therm QW shown fixed by battens. With uneven walls QUINN-therm QW should be fixed to battens packed true.
  • set QUINN-therm QF boards on edge around the floor perimeter and extend cavity wall insulation at least 150mm below the top of the slab to reduce thermal bridging at the wall/floor junction.
  • a VCL/slipsheet may be laid above the insulation to protect it from the concrete and to prevent condensation forming at interface of the slab and insulation.


Introduction

QUINN-therm QF (Quinn Floor) is a PIR (polyisocyanurate) insulation board intended for use beneath groundbearing concrete slabs.

QUINN-therm consists of a core of PIR foam bonded on both faces to composite metalised facings; the gas filled cells give QUINN-therm its high thermal performance and strength.

Insulating beneath the floor slab brings the mass of the concrete within the insulation envelope, giving the building a steady thermal response. The design minimises thermal bridging and offers a straightforward construction sequence.

QUINN-therm is ideal for insulating floors beneath the slab: its high compressive strength enables it to withstand the dead and imposed loads transferred through the slab for domestic and light commercial applications, and it has a very low rate of moisture absorption. The low thermal conductivity of QUINN-therm minimises the thickness required for the floor to meet the heat loss standards of building regulations.


Installation Guidance

  1. Level the surface of the hardcore with a blinding of clean sand. Ensure finished deflection is less than ±5mm over 3m.
  2. Lay the damp-proof membrane (DPM). Lap joints by 300mm and seal. Lap and seal with the damp-proof course (DPM): with joints lapped 300mm and sealed. Take up to the dpc and sealed.
  3. Fit QUINN-therm against perimeter walls to form edge insulation. The insulation should be deep enough to reach the top of the slab.
  4. Lay QUINN-therm QF boards in broken bond. Butt boards tightly together and to edge insulation. Overlay with polyethylene slip sheet/vapour control layer.
  5. Lap edges and turn up at perimeters. Lay the floor slab and screed.


Notes

  • At service penetrations cut QUINN-therm neatly to fit.
  • Protect exposed edge insulation at surface of slab until it is covered by skirting and/or wall plaster.
  • Use barrow boards when laying the slab to prevent damaging to the insulation. Ensure QUINN-therm boards extend below the level of floor insulation.


Handling and Storage

QUINN-therm QF boards are supplied in shrink-wrapped packs. Store boards under cover and out of direct sunlight, keeping boards flat. When handling QUINN-therm QF do not knock corners and edges. Cut QUINN-therm with a fine tooth saw or trimming knife.



Product Data
Properties Value QUINN-therm QF
Board width x length mm 2400 x 1200**
Board thickness mm 20 - 200
Board density kg/m3 26 - 32
Area per board m2 2.88
Edge profiles available   Butt edged
 
Performance Data
Properties Value QUINN-therm QF
Thermal conductivity* W/mK 0.023
Water vapour resistivity MNs/gm ~ 400
Compressive strength kPa >120

* quoted in accordance with BS EN 13165:2001 ‘Thermal insulation for Buildings - factory made polyurethane foam products’.
** other sizes may be available upon request.